UN Markings on IBCs and How to Check Suitability Under ADR

A factory needs to ship 900 litres of solution tomorrow. The warehouse has a spare 1,000-litre intermediate bulk container (IBC). The photo shows a straight cage, a closed valve and a UN symbol on the plate. “Can we use this one?” asks the warehouse supervisor. A few figures will settle the question. In this example there would be 100 litres of space left in the container, yet the proposed load would still be too heavy.
This IBC has a familiar design, with a rigid plastic bottle inside a steel cage. Before filling it for road carriage under ADR, the consignor needs to answer three questions. Does the packing instruction allow this design for the product? Is the proposed fill within its limits? And is this individual IBC still fit for use?
How to read the identification plate
31HA1/Y/04 24/D/EX 042/0/1250 is an illustrative string following the UN packaging symbol. The mark shows conformity with a tested design type. The manufacturer and design identifiers used here are examples.
Field | How to read it |
|---|---|
31HA1 | 31 identifies an IBC for liquids. HA1 indicates a composite design with a rigid plastic inner receptacle and steel outer casing. |
Y | A performance level for packing groups II and III. Z covers group III only. In the IBC marking system, X for groups I, II and III applies to IBCs for solids. |
04 24 | The IBC was manufactured in April 2024. Look separately for the last inspection date. |
D / EX 042 | D identifies Germany as the state that authorised allocation of the mark. Next come the illustrative manufacturer and design identifiers. |
0 / 1250 | A zero in the stacking test load field means the IBC is not designed to be stacked. Another IBC must not be placed on top. The maximum permissible gross mass, including the IBC, is 1,250 kg. |
A filled IBC can carry another number, such as UN 1824 for sodium hydroxide solution. That number identifies the contents. The guide to dangerous goods marks and labels covers the markings applied for the shipment.
Does the packing instruction allow this IBC?
Suppose section 14 of the supplier’s safety data sheet (SDS) lists UN 1824, Class 8, packing group II for the solution. The consignor looks up the packing group II entry in ADR Chapter 3.2, Table A. Column 8 lists packing instruction IBC02. It allows, among other designs, composite IBCs of type 31HZ1. In this design code, Z is a placeholder for the material of the outer casing. Steel takes the letter A. The 31HA1 design and Y performance level therefore pass the first check. For a different product or packing group, look up the applicable instruction and any special packing provisions in column 9a of the relevant entry.
Before booking caustic soda transport, establish which materials the liquid will actually touch. The bottle plastic might suit this concentration while the seal in the fitted valve still needs checking. Match the exact grade, filling temperature, bottle material, valve and seals to the IBC maker’s data or documented compatibility evidence for this combination. For a returnable unit, establish what it last contained and how it was cleaned. Unidentified residue at the outlet is a reason to hold off filling. When shipping chemical products, compatibility extends to every part in contact with the load.
Why 900 litres can overload a 1,000-litre IBC
In this order the solution has a density of 1.33 kg/l at the filling temperature. The plate gives the empty IBC’s tare mass as 60 kg. The warehouse can check the proposed fill before connecting the hose.
900 litres × 1.33 kg/l = 1,197 kg of product. Add the IBC and the gross mass is 1,257 kg.
The plate allows 1,250 kg. There is headspace, yet the load exceeds the gross mass limit by 7 kg. If the customer needs all 900 litres, select a suitable IBC with a higher gross mass rating or agree to split the shipment. For each unit, check the degree of filling and allow for thermal expansion on the journey. When planning packaged freight transport, give the carrier the actual gross mass of each package. If another IBC carries a non-zero stacking test load, read its separate stacking pictogram for the permissible load on top in service.
Checking the age of the bottle and the inspection dates
Imagine the warehouse is preparing this IBC for a fresh fill in November 2026. The cage plate says “04 24”. For a composite IBC, also look for the manufacture date on the plastic bottle or the prescribed duplicate marking on the outer casing. The dates on the assembly and the inner receptacle can differ. Under ADR 4.1.1.15, the normal period of use for carriage of dangerous substances is five years from manufacture of the plastic receptacle, unless the competent authority approves otherwise. Some substances have a shorter permitted period.
The inspection timetable is a separate check. The IBC’s external condition and service equipment must be examined at intervals of no more than 2½ years. A composite IBC for liquids also needs a leakproofness test before first use and at intervals of no more than 2½ years. A fuller inspection covering conformity with the design type, internal and external condition and service equipment takes place before entry into service and at intervals of no more than five years (ADR 6.5.4.4). The owner keeps the records. Repairs trigger the prescribed inspections and tests before reuse.
If April 2024 is the last documented inspection and leakproofness test, the 30-month interval expired in October 2026. For a fresh fill in November, the owner needs evidence of subsequent checks or must arrange the required inspection and test before use. A recent inspection stamp does not restart the bottle’s five-year period of use.
What to ask the warehouse for before collection
Ask for photos of the full UN marking and the additional plate data, the bottle date, the valve and lower connection, and the whole assembly including its pallet. Match the last inspection and leakproofness test dates to the owner’s records. Examine the outlet area, points where the cage touches the bottle, and the forklift entry points. Hold the fill if there is a crack, evidence of leakage or a cage member pressing into the bottle. Resolve the defect or select another unit. If mandatory marks are illegible, have them properly restored or use an IBC with legible marks.
For a dangerous goods road freight booking, provide the consignor’s classification, package count, proposed fill volume and gross mass, and stacking restrictions. The warehouse supervisor can now give a clear answer. The planned 900 litres must go in different packaging. The gross mass already rules it out, and its inspection status still needs confirming before any fresh fill.